Standardized customization of 12 kV ring main unit (box)
In order to meet the general interchangeable use of equipment from different manufacturers in a certain range and a certain period, and improve the convenience of operation and maintenance of ring main units, the Company organized China Electric Power Research Institute, design institutes, operating units, manufacturing enterprises, testing institutions and other units to carry out standardized design work such as typical structural schemes and primary interfaces of ring main units. This standardized design of 12 kV ring main units is aimed at SF6 gas insulated ring main units which are widely used at present, taking into account the requirements of environmental protection gas insulated ring main units, solid insulated ring main units and atmospheric sealed air insulated ring main units. When a fault occurs in the operation process or a quality problem is found in the products of an enterprise by random inspection, it is convenient to directly replace the equipment of other manufacturers by lifting the indoor single cabinet or outdoor ring main unit, and the internal structure of the products of each manufacturing enterprise can be designed differently.
Key words:
Category:
Detail
Product overview:
According to the Company's "1135" distribution network operation service management requirements, improve equipment selection standards, improve quality control system, enhance the durability of distribution network equipment, highlight the good core of equipment, and comprehensively promote the standardization of distribution equipment according to the principles of safety, reliability, firmness and durability, unified standards and universal interchangeability.
Technical parameter:
Project name |
Unit |
Data |
remark |
Rated voltage (kV) |
KV | 12 | VVF/VVV单元 |
Rated frequency |
HZ | 50 |
VVF/VVV单元 |
Rated current |
A | 630 |
VVF/VVV单元 |
Maximum fuse current |
A | 125 |
VVF/VVV单元 |
Rated short-time withstand current |
KA | 25 |
VVF/VVV单元 |
Rated short circuit duration |
S | 4 |
VVF/VVV单元 |
Rated peak withstand current |
KA | 63 |
VVF/VVV单元 |
Rated short-circuit breaking current |
KA | 50 |
VVF/VVV单元 |
Transfer current |
A | 1700 |
VVF/VVV单元 |
Main loop resistance |
μΩ | ≤150 |
VVF/VVV单元 |
Rated short-time withstand current of grounding switch |
KA | 25 |
VVF/VVV单元 |
Rated short-time duration of grounding switch |
S | 3 |
VVF/VVV单元 |
1 min rated short-time power frequency withstand voltage (phase to phase, to ground) |
KV | 42 |
VVF/VVV单元 |
Rated lightning impulse withstand voltage (phase to phase, to ground) |
KV | 75 |
VVF/VVV单元 |
Overall dimensions (width * depth * height) |
mm | (375/420)*751*1950 |
VVF/VVV单元 |
Mechanical life |
time |
5000 |
VVF/VVV单元 |
Level of protection |
IP4X |
VVF/VVV单元 |
Product inquiry
Related products
Contact us
Tel:+86-371-55033377
Fax:+86-371-55033377
Email:hnyuhe@vip.126.com
Factory address: North Section of Xueyuan Road, Luoxin Industrial Cluster Area, Luoyang City
Social media

Mobile terminal
Copyright©Henan Yu He Electrical Co., Ltd.
This website already supports IPV6 Business license Powered by www.300.cn | SEO
SAF Coolest v1.3 设置面板 PBISS-ANSZ-YSZSE-WXV
无数据提示
Sorry,当前栏目暂无内容!
您可以查看其他栏目或返回 首页